Selection guides / Sensors · DI · 4–20 mA

LoRaWAN Sensor Selection: Environment, DI and 4–20 mA

For new monitoring points, choose by temperature, humidity, leaks or air quality. For existing instruments, start with dry-contact, current or voltage outputs. Confirm the signal type first, then channels, power and configuration.

LoRaWAN Sensor Selection: Environment, DI and 4–20 mA — ManThink
ManThink technical article cover

In this article

New measurements or existing signals?

For a new monitoring point, first specify the physical quantity: room temperature and humidity, water on the floor or air quality, for example. For existing equipment, inspect its wiring and manual to identify the signals it can output.

For example, a pressure instrument measures pressure while KS31 acquires its analog output. Distinguish the field probe from the signal-acquisition device; an analog collector does not contain every possible sensing probe.

Match requirements to interfaces and models

KS31 current and voltage inputs are different configurations. KS32 dry-contact inputs are not direct substitutes for active voltage inputs. Confirm the site signal, then follow the corresponding wiring instructions.

Match requirements to interfaces and models
Site requirementModelKey checks
Temperature/humidity, optionally with leak detectionKS52Spot/rope probes and order configuration
Air-quality monitoringKS61Actual measurements, ranges and power configuration
Switch states and dry-contact feedbackKS32Contact type, channels and wiring conditions
Instrument current or voltage outputKS31The matching 4–20 mA or 0–10 V configuration

Apply this guide to your project

ManThink offers IoT products for device connectivity, networking and data applications. Explore the following product resources alongside the engineering guidance in this article:

KS52 Temperature, humidity & leak sensor · ThinkLink

Explore ManThink products and discuss your project →

Other decisive specifications

  • Whether the measurement range and accuracy meet operational needs.
  • Required input channels and whether probes and accessories are included.
  • Battery or external power, acquisition and reporting intervals.
  • Installation location, operating environment and protection requirements.
  • Whether the device frequency band matches the site’s LoRaWAN network.

Do not rely on model prefixes alone. Keep records of site outputs and wiring and check each requirement against the exact product page to avoid discovering incompatible interfaces during installation.

Sources

Refer to the corresponding official documentation and confirmed configuration for exact models, interfaces and options.

MANTHINK

Become a ManThink Partner

Work together on IoT projects for buildings, HVAC and campuses.

Leave your email if you would like us to contact you.

Your submission is emailed to the ManThink business team for this enquiry. Do not include passwords or sensitive information.

info@manthink.cn ↗