# EdgeBus equipment retrofits — ManThink

> Connect existing equipment with data collectors and the lightweight EdgeBus JavaScript VM. Develop acquisition logic with AI assistance and link applications over LoRaWAN.

Canonical: https://www.manthink.cn/en/edgebus/

EDGEBUS / PROGRAMMABLE ACQUISITION FOR EXISTING EQUIPMENT

Connect existing interfaces with collectors. Adapt device protocols with EdgeBus / JS.
Bring working instruments and sensors into AI-powered IoT applications.

[Choose a collector  ↗](https://www.manthink.cn/en/products/collectors/) [EdgeBus technical details](https://www.think-link.net/zh/edgebus/) [Integrated devices ↓](https://www.manthink.cn/en/edgebus/#integrated-devices)

![Example of on-site piping and instruments](https://www.manthink.cn/assets/legacy-instruments.jpg)
Keep existing equipment · Check outputs and protocols first

![KC21 IP65 RS-485 collector — product image](https://www.manthink.cn/assets/kc21.png)
KC21 / EdgeBus

FEATURED EDGEBUS / KC25

## Compact in the cabinet. Open to your protocols with JS.

DIN-rail RS-485 collector with the lightweight EdgeBus JS virtual machine.
From standard to custom protocols, connect existing equipment to LoRaWAN.

DIN-rail mounting  69 × 25 × 25 mm  DC 5–24 V

[Discover KC25 ↗](https://www.manthink.cn/en/products/collectors/kc25/) [Explore other interfaces ↗](https://www.manthink.cn/en/products/collectors/)

Use JavaScript to implement acquisition and parsing for protocols on the RS-485 interface.

![KC25 Compact DIN-rail RS-485 EdgeBus collector](https://www.manthink.cn/assets/kc25.jpg)

**RS-485** Connect existing equipment  **JS** Programmable protocols  **LoRaWAN** Wireless data to the platform

FROM FIELD TO APPLICATION

## The right product for every step, from field to application.

![Example field instruments](https://www.manthink.cn/assets/legacy-instruments.jpg)
01 / EXISTING EQUIPMENT 

### Keep the instruments in place

Check output interfaces, device addresses and protocols.

![KC25 DIN-rail RS-485 collector — product image](https://www.manthink.cn/assets/kc25.jpg)
02 / ACQUIRE & PROCESS 

### Collector + EdgeBus

Run JS acquisition logic to parse, convert and aggregate data.

![GD61 Indoor LoRaWAN gateway — product image](https://www.manthink.cn/assets/gd61.png)
03 / WIRELESS ACCESS 

### LoRaWAN gateways

Deliver wireless sensor data to the network and application platform.

![ThinkLink micro-app demo](https://www.manthink.cn/assets/thinklink-shared-demo.png)
04 / APPLICATIONS & OPERATIONS 

### ThinkLink

From data and alerts to AI operations and micro-apps.

AI + JAVASCRIPT

## Develop with AI. Execute on the device with EdgeBus.

A lightweight JavaScript VM lets acquisition logic adapt to your site.

01 / ADAPT 

### Adapt field protocols

Write, review and debug acquisition programs against device protocols and existing instrument data formats.

02 / PROCESS 

### Process data at the edge

Validate, convert, aggregate and report changes on the collector, shaping wireless payloads to your needs.

03 / EVOLVE 

### Evolve with your application

Adjust parameters and sampling intervals or update programs within device and firmware capabilities.

ALREADY CONNECTED / Integrated devices

## Already connected with EdgeBus.

From utility meters and industrial sensors to building and agricultural equipment.
Find integration notes by model and protocol to start your retrofit.

[View all integrated devices](https://www.think-link.net/zh/devices/)

![ZENNER DN25 / DN40 water meter — reference image](https://www.manthink.cn/assets/integrated-21121.webp)

Utility metering 

### ZENNER DN25 / DN40

Water meter

- **Protocol**: Modbus RTU

Read integration documentation

[Utility meteringZENNER DN25 / DN40Water meterProtocolModbus RTURead integration documentation ↗](https://www.think-link.net/docs/zh/Integration/Device/meter/KC21-21121-ZENNER.html) ![DDZY2397 Single-phase smart meter with tariff control — reference image](https://www.manthink.cn/assets/integrated-23114.webp)

Utility metering 

### DDZY2397

Single-phase smart meter with tariff control

- **Protocol**: DL/T 645

Read integration documentation

[Utility meteringDDZY2397Single-phase smart meter with tariff controlProtocolDL/T 645Read integration documentation ↗](https://www.think-link.net/docs/zh/Integration/Device/meter/23114-DDZY2397.html) ![T100 Industrial temperature sensor — reference image](https://www.manthink.cn/assets/integrated-22105.webp)

Industrial sensing 

### T100

Industrial temperature sensor

- **Protocol**: Modbus RTU

Read integration documentation

[Industrial sensingT100Industrial temperature sensorProtocolModbus RTURead integration documentation ↗](https://www.think-link.net/docs/zh/Integration/Device/Industry/22105-T100.html) ![DYP-A17 ultrasonic level sensor — reference image](https://www.manthink.cn/assets/integrated-22112.webp)

Industrial sensing 

### DYP-A17

Ultrasonic level sensor

- **Protocol**: Modbus RTU

Read integration documentation

[Industrial sensingDYP-A17Ultrasonic level sensorProtocolModbus RTURead integration documentation ↗](https://www.think-link.net/docs/zh/Integration/Device/Industry/22112-A17.html) ![UMTH4 Temperature and humidity transmitter — reference image](https://www.manthink.cn/assets/integrated-21311.webp)

Building environment 

### UMTH4

Temperature and humidity transmitter

- **Protocol**: Modbus RTU

Read integration documentation

[Building environmentUMTH4Temperature and humidity transmitterProtocolModbus RTURead integration documentation ↗](https://www.think-link.net/docs/zh/Integration/Device/BMS/21311-UMTH4.html) ![BGT-SMPS multi-parameter soil sensor — reference image](https://www.manthink.cn/assets/integrated-25101.webp)

Smart agriculture 

### BGT-SMPS

Multi-parameter soil sensor

- **Protocol**: Modbus RTU

Read integration documentation

[Smart agricultureBGT-SMPSMulti-parameter soil sensorProtocolModbus RTURead integration documentation ↗](https://www.think-link.net/docs/zh/Integration/Device/Agriculture/25101-BGT-SMPS.html)

Selected third-party integrations. See the documentation for models, wiring and adapters; the full list is maintained on the ThinkLink website.

START WITH YOUR INTERFACE

## Start with the interface you already have.

**RS-485** 

KC21 · KC25

View collectors ↗

[RS-485KC21 · KC25View collectors ↗](https://www.manthink.cn/en/products/collectors/?signal=rs485) **M-Bus** 

KC22

View collectors ↗

[M-BusKC22View collectors ↗](https://www.manthink.cn/en/products/collectors/?signal=mbus) **Infrared** 

MC11

View collectors ↗

[InfraredMC11View collectors ↗](https://www.manthink.cn/en/products/collectors/?signal=infrared)

**DI / 4–20 mA / 0–10 V inputs** 

Choose KS32 / KS31 signal-acquisition products according to the input type.

[Analog-input products ↗](https://www.manthink.cn/en/products/sensors/ks31/) [Dry-contact products ↗](https://www.manthink.cn/en/products/sensors/ks32/)

A supported interface does not guarantee protocol compatibility. Check device protocols, acquisition software, power and firmware. Mechanical instruments need an accessible signal output.

THE NEXT CONNECTION / APPLICATIONS START HERE

## Once your devices are connected, let ThinkLink take it from there.

A general-purpose, AI-powered IoT platform with native LoRaWAN.
LoRaWAN / 4G connectivity, AI operations and micro-app development. Free self-hosting, one-command installation and customizable branding.

[Get the install command ↓](https://www.manthink.cn/en/#thinklink-deploy) 

[Discover ThinkLink](https://www.think-link.net/zh/) [ThinkLink App](https://www.think-link.net/zh/mobile/thinklink/) [TapLink](https://www.think-link.net/zh/mobile/taplink/)

[![Snapshot of a ThinkLink building micro-app demo](https://www.manthink.cn/assets/thinklink-shared-demo.png)
Micro-app demo · Try it online ↗](https://thinklink.manthink.cn/tkl-dashboard-web/#/custom-page-share/demo/91vpc9x9mqsx75ii)

Find products that fit your site.

## Tell us about your interfaces, power and installation.

[Ask about selection  ↗](mailto:info@manthink.cn?subject=ManThink+product+selection+inquiry)